Grease interceptors must be located in spaces that stay above 40°F to keep fats from solidifyingUnder operating conditions, a grease interceptor may not be located in an area where surrounding temperatures are below what threshold?How Fast Must Large Horizontal Drain Pipes Flow When Half Full?For horizontal drain piping that is 4 inches or larger in diameter, what minimum computed velocity must it achieve when flowing half full?Minimum storm sump depth in Wisconsin plumbing is 22 inches for reliable pump operationWhat is the minimum depth for a storm sump?NFPA 13D Covers Multipurpose Piping in Residential Sprinkler SystemsMultipurpose piping systems are designed and installed in accordance with which NFPA standard?Understanding discharge size for a non-grinder sewage ejector in residential plumbingDischarge size for a non-grinder ejector?Understanding wet venting between two fixtures in Wisconsin plumbing: minimum 2-inch drain and sizing ruleIn wet venting between two fixtures, the drain between the two fixtures must be at least one pipe size larger than the upper fixture drain and not smaller than what diameter?What is the minimum vent connection height above the floor in Wisconsin plumbing?Minimum vent connection height above floor?What’s the minimum setback between a well and POWTS, cemetery, or storm water pond in Wisconsin?What distance is required between a well and a POWTS dispersal component with a design capacity of less than 12,000 gallons per day, a cemetery, or a storm water retention or detention pond?When do vents need to be added for drain stack offsets over 45 degrees in Wisconsin plumbing?For venting offsets more than 45 degrees in drain stacks, when must vents be provided?
More practice questions

These questions are part of the practice quiz. Start practicing

  • Backwater protection: where should a backwater valve be located?
  • What is the maximum vertical distance allowed between the top of the fixture drain outlet and the horizontal centerline of the trap outlet?
  • For underground piping greater than 2 inches in diameter, what is the maximum developed length between cleanouts?
  • What is the minimum separation distance between a water well and the property line?
  • Which statement about Department Plan approvals is correct?
  • All gravity horizontal drains within or under a building shall be accessible through what?
  • Sanitary building sewers 6 inches or less have manholes located not more than how many feet apart?
  • ANSI stands for which organization?
  • Floor drains may not be installed in which rooms?
  • What is the minimum flow velocity that must be maintained in pressurized sewers?
  • What are the minimum center and edge depths for the mound cover?
  • Traps shall be designed to be self-scouring. P traps shall be considered self-scouring. Which statement is true?
  • What is the purpose of the observation pipes being installed at an elevation to view the horizontal or level infiltrative surface within the dispersal cell?
  • Observation pipes should be located near the dispersal cell ends. Which option best reflects this requirement?
  • What components constitute the minimum depth of the mound distribution cell?
  • Under stable bottom conditions, the trench bottom must be bedded and initially backfilled to comply with which of the following?
  • Which statement best describes SPS Intent?
  • If one or more interior grease interceptors are provided, wastes from a food waste grinder or sanitizing compartment of a sink or a rinse compartment of a sink may bypass the interceptor(s).
  • Under stable bottom conditions, after ensuring bottom is dry, what is the required action for the trench?
  • Bedding shall be sufficiently dry.
  • Which of the following is an acceptable air test pressure for sanitary sewers?
  • What minimum flow velocity must pressurized sewers maintain?
  • For frost protection, insulation must be installed at a minimum of how many inches below finished grade and how many inches above the top of the sewer pipe?
  • Observation pipes must be located at least how many inches from the end wall and sidewall?
  • What is the maximum vertical distance between the top of the fixture drain outlet and the horizontal center line of the trap outlet?
  • For a kitchen sink, which connection is prohibited for the trap to a vertical drain?
  • What is the required height range for a residential clothes washer standpipe above the trap outlet centerline?
  • Private interceptor mains six inches or larger must have a manhole at the most upstream point and at intervals not more than what distance, and at every 45-degree change in direction?
  • How much backfill cover must be provided over the top of the pipe before the trench is wheel-loaded?
  • Which of the following best defines a horizontal reference point?
  • What is the minimum separation distance between sanitary sewers and private water system wells?
  • No grease interceptor may be installed where the surrounding temperatures under operating conditions are less than 40°F. Which option describes this requirement?
  • For an air test of drain and vent systems, the test pressure is 5 psi, or is sufficient to balance a mercury column of how many inches in height?
  • Rough-in inspection shall be made when which of the following?
  • If any portion of an above-ground building drain discharges to a vertical pipe, to what must the building drain connect?
  • What is the minimum separation distance between a water well and a swimming pool in ground?
  • SPS PURPOSE refers to safety and sanitation of plumbing in connection with which of the following?
  • What is the discharge size for a sewage grinder outlet?
  • Which statement accurately describes the mound distribution cell dimensions?
  • What is the consequence if the above-ground portion of a building drain discharges into a vertical pipe according to the rules?
  • Which statement best defines a horizontal reference point?
  • Which statement correctly pairs discharge sizes with the type of ejector?
  • A continuous-flow drainage device discharges 5 GPM. How many drainage fixture units (DFU) should be assigned?
  • What sump pit size configurations are listed?
  • What is the minimum separation distance between a water well and a swimming pool in-ground?
  • In the case of large stones or bedrock, what materials must be used to backfill the trench to grade?
  • A horizontal reference point is used to relate horizontal dimensions to what?
  • Boiler relief discharge must dump to indirect waste via an air-gap. Which option describes this method?
  • When large stones or bedrock are encountered, the bedding material backfill to grade must be what?
  • What is the maximum developed length between underground cleanouts for piping greater than 2 inches?
  • SPS Intent includes protecting which of the following?
  • When may the trench be excavated to grade if the trench bottom does not contain stone larger than one inch and bedrock is not encountered?
  • What is the minimum bottom diameter for a storm sump?
  • Duplex pumping systems include what type of alarm?
  • Which statement is true about check valves in the system?
  • Sump pits are sized to operate for how many seconds?
  • What is the maximum developed length above ground for a drain pipe before a cleanout is required?
  • Which statement reflects SPS PURPOSE?
  • Which statement correctly lists the minimum dimensions for a sump?
  • TSS stands for which of the following?
  • Regarding mound fill depth, what is the required minimum and maximum fill depth?
  • Local inspection: In municipalities with a local inspector, testing of the plumbing shall be done in the presence of a plumbing inspector.
  • What is the minimum depth of extruded polystyrene foam insulation below finished grade for frost protection?
  • In garages for public buildings where a drain receives wastewater from floor areas used by vehicles, how must wastewater from areas where vehicles will be serviced discharge?
  • Exterior stormwater inlets subject to vehicular traffic must be set on a suitable base capable of sustaining what?
  • Which of the following is an acceptable method for backwater protection?
  • What is the minimum separation distance between a water well and a POWTS holding tank?
  • Where any portion of an above-ground building drain discharges to a vertical pipe, the building drain shall connect to which?
  • Private interceptor main sewers 6 inches or larger must have a manhole at the most upstream point of the private main, and what spacing and angle requirements?
  • Trap seal depth (general) is between which measurements?
  • Backfill should be completed at what distance before the wheel is loaded?
  • Which temperature threshold prohibits installation of a grease interceptor when ambient temperatures fall below it?
  • What is the minimum separation distance between a water well and a school well?
  • What is the minimum depth of extruded polystyrene foam insulation below finished grade for frost protection?
  • In municipalities with a local plumbing inspector, testing of the plumbing shall be performed in the presence of a plumbing inspector.
  • The "I" section on a mound sheet indicates which characteristic?
  • What is the minimum diameter for an exterior sump pump vent line?
  • If any portion of an above-ground building drain discharges to a vertical pipe, the building drain shall connect to which?
  • SPS Intent requires plumbing in buildings intended for human occupancy to be installed and maintained to protect which of the following?
  • Branch connections from interior clearwater inlets must not connect downstream from the base fitting within which distance?
  • For garage floor drainage in public buildings, the pressurized drain piping from the garage floor must terminate inside the basin with a 6-inch submerged inlet and be at least how many inches above the basin floor?
  • In garage floor area wastewater systems, what size submerged inlet must the drain terminate with inside the basin?
  • Test methods for drain and vent systems require what?
  • Bedding shall be sufficiently dry and hand or mechanically what?
  • What is the maximum horizontal length allowed for indirect waste piping and local waste piping handling sanitary wastes?
  • Traps shall be self-scouring and shall not have interior partitions except where what is integral with the fixture?
  • In municipalities with a local plumbing inspector, testing shall be done in the presence of the inspector unless otherwise provided.
  • Which of the following best defines a horizontal reference point?
  • What is the maximum developed length between cleanouts for underground piping greater than 2 inches?
  • Exterior sump on a simplex system must have a minimum holding capacity above the high level alarm of at least how many days?
  • All hospitals shall be provided with at least how many water services?
  • Which statement correctly describes the maximum horizontal and vertical lengths for indirect waste piping and local waste piping?
  • For residential clothes washer standpipes, the receptor shall terminate at what range above the floor?
  • Which statement about manhole openings is true?
  • The exterior sump holding capacity above the high level alarm is required when installed on which type of system?
  • Which device is a watertight receptacle for the collection and holding of wastewater?
  • What is a Dispersal Zone?
  • In vertical wet venting, when two wall outlet fixtures are on the same floor level with their drains connecting to the same vertical drain at different elevations, the lower fixture drain may be wet vented only if which condition is met?
  • What is the minimum separation distance between a water well and a property line?
  • In a kitchen sink installation, the horizontal drain piping serving the sink trap shall not connect to a vertical drain by means of which configuration?
  • Which facility is associated with the 400-foot separation requirement from a well?
  • A floor outlet water closet shall connect to which size elbow?
  • During drain and vent system testing, which gauge pressure is used for the air test?
  • Where must all building drains be installed in relation to the lowest floor levels, assuming sewer elevation permits?
  • Sanitary drains continuous flow devices: drainage fixture unit values shall be computed on the basis of how many fixture units per 1 GPM of flow?
  • On a simplex pumping system, what alternative may be provided instead of the specified duplex pumping equipment?
  • What is the expiration period for a sanitary permit?
  • Which of the following is NOT part of mound site preparation?
  • Exterior stormwater inlets subjected to vehicular traffic must be set on a base capable of withstanding what?
  • The E Horizon is best described as which of the following?
  • When a building drain above ground discharges to a vertical pipe, to what elevation above the basement must the building drain connect to the building sewer?
  • For wastewater treatment and holding devices, inspection without a manhole opening is possible with an opening of what diameter?
  • Total suspended solids (TSS) are defined as what?
  • Department Plan approval shall expire after how long if construction has not commenced?
  • What is the holding tank defined as?
  • Under which condition is frost protection not required for building sewers?
  • Which term is defined as a device or method to promote the assimilation of treated wastewater by the environment?
  • Floor drains are generally prohibited in which rooms, unless exceptions apply?
  • For a stormwater manhole with a 42-inch diameter, the access opening must be at least how wide?
  • The discharge from boiler relief valves must enter indirect waste through which component?
  • If stone larger than one inch is present or bedrock is encountered, the trench shall be excavated to a depth at least how many inches below the grade elevation?
  • Branch drains from interior clearwater inlets may not connect downstream from the base fitting of a drain stack within a distance equal to how many pipe diameters?
  • Which floor levels are used to determine the building drain elevation?
  • What is the maximum vertical length of indirect waste piping?
  • What is the purpose of breaking up the top 7-8 inches perpendicular to the slope during mound site prep?
  • What is the expiration condition for Department Plan approval?
  • Minimum well clearance distance from a well to a leach field?
  • Which phrase best completes the SPS PURPOSE definition?
  • For offsets in drain stacks, where must the vent be located?
  • Stormwater gravity drains shall not be combined with clearwater drains prior to discharging to the storm building drain unless approved by whom?
  • Which statement about POWTS dispersal component is correct?
  • Which statement about rough-in inspection is correct?
  • Storm building sewers 10 inches or less in diameter require cleanouts not more than how far apart?
  • What is a horizontal reference point?
  • Which statement best describes a POWTS dispersal component?
  • In vertical wet venting, which condition allows the lower fixture drain to be wet vented?
  • What is the minimum dimension for manhole openings?
  • Which device would be considered a continuous-flow device for drainage fixture unit calculations?
  • For sanitary building sewers 6 inches or smaller, what is the maximum distance between manholes?
  • When duplicate pumps are installed, what type of valve is required downstream of each full-flow check valve?
  • Who is responsible for ensuring that the operation and maintenance of a POWTS occurs in accordance with this chapter and approved management plans under SPS 383.54(1)?
  • What is the minimum discharge size on a grinder pump?
  • What is the minimum separation distance between a water well and a building?
  • What is the minimum size of an exterior sump pump vent line?
  • For above-ground piping, what is the maximum developed length between cleanouts?
  • What is the minimum separation distance between a water well and a school well?
  • Which statement best defines the Dispersal Zone?
  • Which statement accurately describes a restriction on grease interceptors?
  • What is the primary purpose of bedding and backfill for building drainage trenches?
  • Which statement is NOT part of mound site preparation?
  • Stormwater gravity drains may be combined with clearwater drains prior to discharging to the storm building drain only if approved by the department.
  • Hospitals must have at least how many water services?
  • For private interceptor main sewers 6 inches or larger, where must a manhole be located?
  • All gravity horizontal drains within or under a building shall be accessible through a cleanout.
  • In vertical wet venting, the drain between the two fixtures must be at least how large compared to the upper fixture drain?
  • The Soil E Horizon is characterized as which of the following?
  • What is the maximum horizontal length of indirect waste piping and local waste piping handling sanitary wastes?
  • Which statement best describes the Clearwater vent requirement?
  • Which ASTM specification must mound fill material meet?
  • In the installation of a building drain, what size stone is used for the initial backfill under the bottom of the trench when the bottom can be kept stable and free of water?
  • Which statement is true regarding stormwater and clearwater discharge into a sanitary building drain that connects to a POTW?
  • What is the minimum separation distance between a water well and POWTS dispersal (drain field)?
  • Under frost protection rules, which situation does not require frost protection for building sewers?
  • What are the minimum sump dimensions?
  • Total suspended solids (TSS) are defined as...
  • In the presence of bedrock or large stones, the trench depth below grade must be at least how many inches?
  • Under which condition may wastes bypass interior grease interceptors?
  • Minimum well clearance distance from a leach field?
  • Trap seal depth for garage catch basin or elevator pit?
  • For underground piping 2 inches in diameter or less, what is the maximum developed length between cleanouts?
  • The Soil A Horizon is defined as which layer?
  • What is the maximum horizontal distance between the vertical centerline of a fixture drain outlet and the vertical centerline of the trap inlet?
  • Which set of dimensions represents the minimum sump size?
  • Multipurpose piping systems shall be designed and installed in accordance with which standard?
  • What is the minimum top diameter for a storm sump?
  • If one or more interior grease interceptors are provided, which wastes may bypass the interceptor or interceptors?
  • In trench excavation, when the bottom does not contain stone larger than one inch, the trench may be excavated to grade. Which option describes this condition?
  • Edge depth requirement for mound cover states that edges must be at least how many inches deep?
  • What is the minimum separation distance between a water well and POWTS dispersal?
  • Minimum well clearance distance from holding tank?
  • Branch connections from interior clearwater inlets must not connect downstream from the base fittings within what distance?
  • TSS stands for which of the following?
  • If a sump has a top diameter of 16 inches and a bottom diameter of 14 inches, what is the minimum required depth?
  • P-traps shall be considered self-scouring. Which statement is correct?
  • What is the maximum vertical length allowed for indirect waste piping and local waste piping handling sanitary wastes?
  • The A Horizon is best described as which of the following?
Subscribe

Get the latest from Passetra

You can unsubscribe at any time. Read our privacy policy